Product Code: KI-19-501
Body : Well designed heavy & sturdy die casted monocular body inclined to 90o suitable to meet the needs of college and school students. Main features of the Microscope are :
Product Code: KI-19-502
Specifications:
Product Code: KI-19-503
| Spescifications: | |
| Body | Well designed die-casted staple frey and black contrast with hard instrumental Chromium finish. |
| Observation Head | Special quality Binocular observation head inclined at 450 and rotatable through 3600. All prism and optical surfaces are anti refilection coated. Standared interpupillary distance and diopter adjustment provided. |
| Nose Piece | Dust proof quadruple nose piece with clik for perfect optical alignment. |
| Stage | Fixed stage 140mm x 120mm with built - in co-axial mechanical stage for easy and smooth bearing |
| Condenser | Double lens bright field Abbe’s condenser N.A. 1.25 with iris diaphragm movable by rack and pinion. |
| Illumination | By halogen lamp 6V 20 Watts operated through built- in solid state transformer with electronic regulator. |
| Safety Stopper | Prevent damage to slides and objectives. |
| Optics | High class anti reflection coated self centres and parafocal achromatic objectives and superior quality eye pieces. |
| Packing | In dust proof Thermocole Box in 12mm thick beautiful storing cabinet with sunmica door. |
Product Code: KI-19-504
Specifications:
Product Code: KI-19-505
| EYEPIECES : High quality paired eyepieces 10 x (standard), 15 x (optional) extra wide field, high eye reliet type. | ||||||||||||||||
|
||||||||||||||||
Objective : Choice of partocal, parcentered, Semi Plan (SP), Achromatic objectives in magnification range, 4x, 10 x and retractable 40 x and 100x oil.
|
||||||||||||||||
| Terms describing the optical features of microscope | ||||||||||||||||
| Total Magnification : Total magnification of a microscope is the individual magnifying power of the objective multiplied by that of the eyepieces. Numerical Aperture (N.A) : One of the important factors determining the efficiency of condenser and objectives. it is represented by the formula. ( N.A. = n sin a ) Where n is the retractive index of a medium and ‘a’ is half of the maximum angle at which the light rays enter or leave the lens from or to a focussecd object point on the optical axis. Working Distance : Clearance between the from of the objective and the upper surface of the cover glass when the image of a specimen is brought into sharp focus. Generally, the higher the magnifying power of the objective, the shorter the working distance. Field Diameter : Diameter (MM) of the field of view which can be observed through the eyepiece. Indication 10x on the top of the eyepiece shows that eyepiece magnification is 10x |
Product Code: KI-19-506
Specifications:
Product Code: KI-19-508
Accessories Available for the above Microscopes :
|
||||||||||
Optional Accessories :
|
||||||||||
|
Product Code: KI-19-509
| What Makes working on Splendour Microscopes, a ‘Spectacular Vision Experience’? |
| OPTICS |
| Fitted with our time tested DIN Achromatic Objectives, designed as per Ferman Standards of Optical Excellence. Fully Parfocal and perfacity precetered, these Objectives give you details, never seen before Sharper Resolution and extra flat field of view, make viewing a strain - free pleasure Coupled with our Stadared High Eyepoint (25mm) Compensating Extra Wide filed (Filed No.18) Eyepieces they provide a colourfree image. The Standerd Microscops is supplied with four Objectives-Achro 4X, Achro 10X, Achro 40X(SL) and Achro 100X Oil (SL), and a pair of WF 10X/18 Eyepieces.40X(SL) and Achro 100X Oil (SL), and a pair of WF 10x/18 Eyepieces. Huy.6x & WF 15x are available. |
| OBSERVATION HEAD |
| Extra Clarity and High Contrast Bionocular Observation tube, rotatable through 3600 inclined at 450, off the horizontal. Adjustable onterpupillary distances and Diopter adjustment ring on the Occular tube, for correction of eye-aquity. Optionally, 3o0, incliend Sedentopf design Binocular tube can be provided |
| FATIGUE FREE FOCUSING |
| Traveling on Ball slides The Co-axial focusing system, incorporates a very precise and were resistant liner bearing mechanisum that eliminates vibration and backlash. The coarse adjustment knob has a built in control to after the tension of the motion. The touch sensitive fine focus knob a are graduated in 0.02mm increments. |
| LARGE MECHANICAL STAGE |
| The 150X120 mm Stage Plate incorporates a linear bearing mechanism with right hand low - positioned CO-AXIAL movement Control. It has a travel range of 75mm along the X-Axis and 45mm along the Y-Axis for easy scanning of large specimens. A.0 1mm vernier provides accurate location of the specimen area. |
| NOSEPIECE |
| Precision-built quadruple revolving nosepiece, traveling on ball bearing, ensures a common field Center, on changing magnification and reintroduction. The soft ribbed grip for easy rotation, helps prevent damage, from gripping the objectives. |
| Illumination Light Control |
| Built-to a well contoured, Compact Base, with Convenient hand rests, and powered by a 6V-20watts halogen light source, the illumination. The lamp is precentered for your convenience. Replacement of lamp can be done without opening of base or electricals. Light intensity can be varied through electronically controlled knob. The lllumination is furhter enhanced through well designed illimonator lens system and a substage Abbe Condenser with N.A. 1.25 and built in lris Diaphragm and Filter Holder. Optinally, the Bright Field Condenser can be easily replaced by Phase Contrast Turret or Dark Field Condenser. |
| ANTI-REFLECTION AND ANTI-FUNGAL PROTECTION |
| Splendour introduces, for the first time, Mould Protection as a standard feature. Mould formation is a menace in most parts of the word, with moderate to high temperatures, high humidity and air pollution. All these factors encourage mould formation which could etch into the optical surfaces and permanently damage them. Splendour’s protection treatment ensures mould-free viewing, a boon in the recent environmental conditioins. All Air-Glass Surfaces of the lenses and Prisms, are ANTI-REFLECTION coated, to eliminate light losses to the maximum |